bild_relais

MK06

描述

MK06为磁场驱动的干簧接近开关,可直接安装在PCB上。此传感器固定在部件的表面上,驱动磁铁安装于活动的表面。干簧传感器与磁铁之间的距离是限定的。靠近或远离磁场将决定干簧开关的吸合或断开。2.54mm PCB脚位间距,另有其它间距。

相关产品:M06壳体磁铁

特点

  • 触点形式有A、B、C和E(保持形)
  • 干簧开关功率高
  • 多种外壳尺寸
  • 五个磁场灵敏范围

应用

  • 通讯
  • 电话压簧开关、键盘和微型开关
  • 家用电器
  • 洗衣机、洗碗机、微波炉/烤箱、冰箱等门控制
  • 低功率信号极限切换
  • 车库门、手动葫芦和传输带
  • 电梯
  • 位置指示器

规格

触点形式 1A, 1B, 1C, 1E (保持形)
额定功率 (W) 0 至 50
切换电压 (VDC) 0 至 500
切换电流 (A) 0 至 1.5
通电电流 (A) 0 至 2.5
最小击穿电压(VDC) 100 至 700
磁场灵敏范围 (AT) 5 至 60

产品搜索


Product search MK06 传感器
No. / Desc.:   
  Item no. DescriptionContact - form
Switching voltage
V
Switching current
A
Pull- In excitation (Reference value)
AT
Overall cable length
MM
Contact rating
W
Carry current
A
Operating temperature
GRAD C
询价 2200050876 2200050876 KSS-BV50876
询价 2206040001 2206040001 MK06-4-BA - NO170 V0.5 A10 W0.5 A-20-85 GRAD C
询价 2206040002 2206040002 MK06-4-CA - NO170 V0.5 A10 W0.5 A-20-85 GRAD C
询价 2206040004 2206040004 MK06-4-EA - NO170 V0.5 A10 W0.5 A-20-85 GRAD C
询价 2206050001 2206050001 MK06-5-BA - NO200 V0.4 A10-15 AT10 W0.5 A-20-85 GRAD C
询价 2206050002 2206050002 MK06-5-CA - NO200 V0.4 A15-20 AT10 W0.5 A-20-85 GRAD C
询价 2206050003 2206050003 MK06-5-DA - NO200 V0.4 A20-25 AT10 W0.5 A-20-85 GRAD C
询价 2206050004 2206050004 MK06-5-EA - NO200 V0.4 A25-30 AT10 W0.5 A-20-85 GRAD C
询价 2206050006 2206050006 MK06-5-GA - NO200 V0.4 A35-40 AT10 W0.5 A-20-85 GRAD C
询价 2206050007 2206050007 MK06-5-HA - NO200 V0.4 A40-45 AT10 W0.5 A-20-85 GRAD C
询价 2206050009 2206050009 MK06-5-OEB - NC200 V0.4 A10 W0.5 A-20-85 GRAD C
询价 2206060000 2206060000 MK06-6-AA - NO200 V0.4 A10 W0.5 A-20-85 GRAD C
询价 2206060001 2206060001 MK06-6-BA - NO200 V0.4 A10-15 AT10 W0.5 A-20-85 GRAD C
询价 2206060002 2206060002 MK06-6-CA - NO200 V0.4 A15-20 AT10 W0.5 A-20-85 GRAD C
询价 2206060003 2206060003 MK06-6-DA - NO200 V0.4 A20-25 AT10 W0.5 A-20-85 GRAD C
询价 2206060004 2206060004 MK06-6-EA - NO200 V0.4 A25-30 AT10 W0.5 A-20-85 GRAD C
询价 2206070001 2206070001 MK06-7-BA - NO180 V0.5 A10 W1.5 A-20-85 GRAD C
询价 2206070002 2206070002 MK06-7-CA - NO180 V0.5 A15-20 AT10 W1.5 A-20-85 GRAD C
询价 2206070003 2206070003 MK06-7-DA - NO180 V0.5 A20-25 AT10 W1.5 A-20-85 GRAD C
询价 2206070004 2206070004 MK06-7-EA - NO180 V0.5 A25-30 AT10 W1.5 A-20-85 GRAD C
询价 2206080000 2206080000 MK06-8-AA - NO100 V0.5 A5-10 AT10 W1 A-20-85 GRAD C
询价 2206080001 2206080001 MK06-8-BA - NO180 V0.5 A10-15 AT10 W1 A-20-85 GRAD C
询价 2206080002 2206080002 MK06-8-CA - NO180 V0.5 A15-20 AT10 W1 A-20-85 GRAD C
询价 2206080003 2206080003 MK06-8-DA - NO180 V0.5 A20-25 AT10 W1 A-20-85 GRAD C
询价 2206080004 2206080004 MK06-8-EA - NO180 V0.5 A25-30 AT10 W1 A-20-85 GRAD C
询价 2206080007 2206080007 MK06-8-HForm C - Changeover175 V0.5 A14-17 AT10 W1 A-20-85 GRAD C
询价 2206080008 2206080008 MK06-8-IForm C - Changeover175 V0.5 A15-23 AT10 W1 A-20-85 GRAD C
询价 2206080009 2206080009 MK06-8-KForm C - Changeover175 V0.5 A16-25 AT10 W1 A20-85 GRAD C
询价 2261084700 2261084700 MK06-10-E84E - bistable NO400 V0.5 A10 W1 A-20-70 GRAD C

技术文献

产品寿命要求

磁铁及其特征

运用领域

测试与测量

测试与测量

线性距离

库存查询


Stock Check

Item no. Distributor Region Quantity Cart RFQ Inventory Date
MK6-5-BFARNELL Europe953RFQ2012/05/23
MK6-5-CFARNELL Europe613RFQ2012/05/23
MK6-8-BFARNELL Europe517RFQ2012/05/23
MK6-8-HFARNELL Europe226RFQ2012/05/23
MK06-10-EDIGI-KEY CORPORATION North America361RFQ2012/05/23
MK06-4-BMOUSER ELECTRONICS North America199RFQ2012/05/23
MK06-4-BDIGI-KEY CORPORATION North America86RFQ2012/05/23
MK06-4-BV50131TTI, INC. North America366RFQ2012/05/23
MK06-4-CDIGI-KEY CORPORATION North America498RFQ2012/05/23
MK06-4EMOUSER ELECTRONICS North America85RFQ2012/05/23
MK06-5-BDIGI-KEY CORPORATION North America397RFQ2012/05/23
MK06-5-CDIGI-KEY CORPORATION North America435RFQ2012/05/23
MK06-6-ADIGI-KEY CORPORATION North America497RFQ2012/05/23
MK06-6-BDIGI-KEY CORPORATION North America336RFQ2012/05/23
MK06-6-BMOUSER ELECTRONICS North America144RFQ2012/05/23
MK06-6-CDIGI-KEY CORPORATION North America253RFQ2012/05/23
MK06-6-CMOUSER ELECTRONICS North America210RFQ2012/05/23
MK06-6-EDIGI-KEY CORPORATION North America500RFQ2012/05/23
MK06-7-BDIGI-KEY CORPORATION North America444RFQ2012/05/23
MK06-7-BMOUSER ELECTRONICS North America122RFQ2012/05/23
MK06-7-CDIGI-KEY CORPORATION North America499RFQ2012/05/23
MK06-8-ATTI, INC. North America32501RFQ2012/05/23
MK06-8-BTTI, INC. North America5251RFQ2012/05/23
MK06-8-BDIGI-KEY CORPORATION North America2665RFQ2012/05/23
MK06-8-BMASTER DISTRIBUTORS North America100RFQ2012/05/23
MK06-8-BMOUSER ELECTRONICS North America90RFQ2012/05/23
MK06-8-CDIGI-KEY CORPORATION North America499RFQ2012/05/23
MK06-8-HTTI, INC. North America7359RFQ2012/05/23
MK06-8-HDIGI-KEY CORPORATION North America500RFQ2012/05/23
MK06-8-HMOUSER ELECTRONICS North America345RFQ2012/05/23
MK06-8-IDIGI-KEY CORPORATION North America498RFQ2012/05/23
MK06-8-IMOUSER ELECTRONICS North America97RFQ2012/05/23
MK6-5-BRELAY SPECIALTIES INC North America58RFQ2012/05/22
MK6-8-HRELAY SPECIALTIES INC North America2RFQ2012/05/22


磁铁运动


Reed Switch & Magnet Actuation
Click to AnimateActuator Type
PositionMovementActuation(s)Contact Form / Mode
Magnet Actuation 1

Bar Magnet

Parallel

Perpendicular

Single

Form A (Normally Open)


Magnet Actuation 2

Bar Magnet

Parallel

Parallel

Single

Form A (Normally Open)

Magnet Actuation 3

Bar Magnet

Parallel

Parallel

Multiple

Form A (Normally Open)

Magnet Actuation 4

Bar Magnet

Parallel

Parallel

Single

Form A (Normally Open)

Magnet Actuation 5

Bar Magnet

Adjacent

Rotary

Multiple

Form A (Normally Open)

Magnet Actuation 6

Ring Magnet

Adjacent

Rotary

Multiple

Form A (Normally Open)

Magnet Actuation 7

Ring Magnet

Adjacent

Rotary

Multiple

Form A (Normally Open)

Magnet Actuation 8

Bar Magnet

Above

Rotary

Multiple

Form A (Normally Open)

Magnet Actuation 9

Bar Magnet

Perpendicular

Perpendicular

Single

Form A (Normally Open)

Magnet Actuation 10

Bar Magnet

Perpendicular

Parallel

Multiple

Form A (Normally Open)

Magnet Actuation 11

Bar Magnet

Parallel

Parallel

Single

Form A (Normally Open)

Magnet Actuation 12

Bar Magnet

Parallel

Perpendicular

Single

Form B (Normally Closed)

Magnet Actuation 13

Bar Magnet

Parallel

Pivot

Single

Form A (Normally Open)

Magnet Actuation 14

Bar Magnet

Magnetic Shield

Fixed

Parallel

Single

Form A (Normally Open)

Magnet Actuation 15

Bar Magnet

Magnetic Shield

Fixed

Perpendicular

Single

Form A (Normally Open)

Magnet Actuation 16

Bar Magnet

Magnetic Shield

Fixed

Parallel

Single

Form A (Normally Open)

延伸产品

壳体磁铁

这些外壳磁体中的任一款均可与上述相应干簧传感器匹配以获得最佳传感器系统解决方案。如果需要其他匹配,请与我们工厂联系获取更多的选择方案。


螺丝安装型壳体磁铁

M02 Magnet M04 Magnet M05 Magnet M12 Magnet M13 Magnet M21 Magnet

圆柱型壳体磁铁

M11 Brass Magnet M11/M8 Plastic Magnet M11/M5 Stainless Magnet

穿孔磁铁

M06 Magnet

常见问题

干簧传感器

Are the hall, reed or emr sensors affected by EDI/RFI?

Are the hall, reed or emr sensors affected by EDI/RFI?

A hall sensor is affected by EDI and RFI and must be protected against them.  Reed sensors and emrs are not affected by EDI or RFI.

Are the hall, reed or emr sensors hermetically sealed?

Are the hall, reed or emr sensors hermetically sealed?

The reed sensor is the only sensor that is hermetically sealed.

What is the output dielectric strength for hall, reed or emr sensors?

What is the output dielectric strength for hall, reed or emr sensors?

A Hall sensors dielectric strength is less than 10 volts, for emrs its typically 250 VRMS, and reed sensors the dielectric strength can be up to 5000 volts.

What is the output capacitance for hall, reed or emr sensors?

What is the output capacitance for hall, reed or emr sensors?

The output capacitance for a Hall sensor is typically 100pf, a reed sensor is only 0.2 pico-farads, and emrs are typically 20 pico-farads.

What is the release time for hall, reed or emr sensors?

What is the release time for hall, reed or emr sensors?

The release time for a Hall sensor is typiclly 5µs, reed sensor 20µs and the emr 5 ms.

What is the operate time for hall, reed or emr sensors?

What is the operate time for hall, reed or emr sensors?

The operate time for a hall sensor is typically 5 µs, a reed sensor is 100µs and the emr is up to 10 ms.

How much current can be switched directly for hall, reed or emr sensors?

How much current can be switched directly for hall, reed or emr sensors?

Hall sensors can not switch any output current, the reed sensor and emr can typically switch up to 2 amps directly.

What is the output voltage range for hall, reed or emr sensors?

What is the output voltage range for hall, reed or emr sensors?

Hall sensors cannot switch any voltage directly.  Reed and emr sensors can switch up to 1000 volts directly.

How much power can you switch direcly with the hall, reed or emr sensors?

How much power can you switch direcly with the hall, reed or emr sensors?

Hall sensors supply a microwatt level signal, reed and emr sensors can switch up to 100 watts directly.

Can one switch loads directly for hall, reed or emr sensors?

Can one switch loads directly for hall, reed or emr sensors?

Only a reed and emr sensor can be switched directly.

What is the output on resistance for hall, reed or emr sensors?

What is the output on resistance for hall, reed or emr sensors?

Hall sensors are typically 200+ ohms, the reed and emr sensors are typically 50 milliohms.

Is hysteresis adjustable for hall, reed or emr sensors?

Is hysteresis adjustable for hall, reed or emr sensors?

Reed sensors can adjust the hysteresis from 35% to 95%.  Hall and EMR sensors have fixed hysteresis.

Is output polarity sensitivity critical for hall, reed or emr sensors?

Is output polarity sensitivity critical for hall, reed or emr sensors?

Yes output polarity is critical for proper switching operation with hall sensors only.

Are external circuits required for hall, reed or emr sensors?

Are external circuits required for hall, reed or emr sensors?

Yes - chopper circuits and drivers are required for the hall sensors only.

Is input polarity sensitivity an issue with hall, reed or emr sensors?

Is input polarity sensitivity an issue with hall, reed or emr sensors?

Only hall sensors are sensitive to input polarity.

Is an applied current required for a change of state with a hall, reed or EMR sensor?

Is an applied current required for a change of state with a hall, reed or EMR sensor?

A current is required for proper operation only on the Hall sensor.

Does a Hall Sensor require extra circuitry?

Does a Hall Sensor require extra circuitry?

Yes, they only supply a small milli-volt signal in the presence of a magnetic field. The signal needs to be amplified and then fed into a switching circuit.

What is Hall Effect?

What is Hall Effect?

A voltage is produced on a semiconductor material when in the presence of a magnetic field.  The voltage is proportional to the strength of the magnetic field.

What switch do I use when switching 5-15 Volts with 10 to 50 milliamps?

What switch do I use when switching 5-15 Volts with 10 to 50 milliamps?

Use ORD228, the ORD211 iridium, or the ORD311.

What switch do I use when switching 15-35 Volts with 10 to 250 milliamps?

What switch do I use when switching 15-35 Volts with 10 to 250 milliamps?

For a sensor use the ORD228 with iridium or the ORD2210 for a relay.

What reed switch do I use for low level switching?

What reed switch do I use for low level switching?

Small electromechanical relays are not good for switching low levels of voltages and currents.  Electromechanical relays need a hefty voltage and/or current to break any film buildup.  It is this film buildup that won't allow very low voltages and currents to pass through the contacts.   Reed switches are clearly the best.  Using sputtered ruthenium contacts or iridium contacts are the best materials for these low level loads.

When do you use an evacuated reed switch?

When do you use an evacuated reed switch?

Switching and breaking voltages of 250 volts and above is best done with a vacuum reed switch.  Up to 4000 volts can be effectively done with the ORD2210V as long as the current levels are not too high.  Above 4000 volts use the Hermetic reed switches.

How much voltage can a pressurized reed switch effectively open?

How much voltage can a pressurized reed switch effectively open?

Miniature reed switches less than 20 mm (0.80 inches) glass length can effectively break up to 250 Volts.  This depends on the pull-in AT (mT) used.  The higher the better.  Reed switches less than 10 mm will shrink this value to around 150 volts.  Minimizing the current flow at the time of opening will improve this value.

What is the signature of a load?

What is the signature of a load?

Reed switches whether they are used in sensors or relays all will be asked to switch some load.  Generally there are two aspects to this load.

  1. Its steady state load
  2. Is the actual switching taking place during the first 50 nanoseconds.  This is also called the the signature of the load. 
This signature takes into consideration not only the steady state load but also any transient voltages or current that may be present during the first 50 nanoseconds.  These transients may be from stray capacitance, inductance in the line and/or common mode voltages.  From a reed switch designer standpoint, the signature is all there is.  The most important time during the switching of a load is that first 50 nanoseconds.  That is when all the damage to the contacts with occur if you are switching the contacts 'hot'.  If a customer is having a problem with early failures, this is the first place to look.  Equally important and not to be overlooked is what voltage and current is actually being broken when the contacts open.  Any healthy voltage and/or current present will chew up the contacts rapidly leading to sticking reed contacts.

How do I know what reed switch to select?

How do I know what reed switch to select?

There are several key factors:

  1. You need to have an idea of the required load.  What voltage and current is being switched at the time of closure for the first 50 nanoseconds?
  2. How many operations will be required during the life of the product?
  3. What are the size requirements?  How much room is needed?
  4. How will the product be mounted? Surface mount, thru hole, etc.
  5. For long life and low levels, use a ruthenium or an iridium sputtered/plated switch.
  6. For switching applications from 50 Volts to 200 volts use the Philips/Coto/Comus sputtered ruthenium switch.
  7. For switching currents 25 ma to 1 amp, the OKI thickly plated rhodium is good along with our STM10 SKS-1A35.
  8. For higher voltages above 200 volts  up to 4000 volts at relatively low current use the  OKI ORD2210V.
  9. For voltages above 1000 volts up to 10,000 volts with higher currents use the Hermetic vacuum switches.  This represents a start.  One could write a book on this subject.  Best to find out the exact customer load and run a life test with a few or several reed switches to make the final determination.

Can a magnet packaged with a reed switch be turned into a temperature sensor?

Can a magnet packaged with a reed switch be turned into a temperature sensor?

A magnet and reed switch can be turned into a temperature sensor by using a magnet that has a certain curie temperature for the temperature you want to sense.  When that curie temperature is reached the magnet loses its magnetic properties whereby the reed switch contacts open.  When the temperature drops below the curie temperature, the reed contacts will close.

参阅有关干簧开关的常见问题(FAQs)

参阅有关干簧继电器的常见问题(FAQs)

参阅有关才磁铁和磁化的常见问题(FAQs)

参阅有关液位传感器的常见问题(FAQs)

参阅有关测试和使用特征的常见问题(FAQs)

参阅有关质量和可靠性的常见问题(FAQs)

在我们的常见问题解答中未找到您所关注的问题吗?请填写“联系表格”来提交新问题。





MEDER electronic Asia Ltd. (亞洲市場) | 上海盟格电子有限公司 (大陆,台湾,韩国,日本市场)| 联系我们 | 版权说明